HOME > Á¦Ç°Á¤º¸ > Reverse Osmosis> Residential |
|
|
|
|
|
|
°¡Á¤¿¡¼ ±ú²ýÇÑ ¹°ÀÇ Á߿伺À» ´õ °Á¶ÇÒ ÇÊ¿ä´Â ¾ø½À´Ï´Ù. °Ç°°ú Á÷°áµÇ¾î ÀÖ´Â ¹®Á¦À̱⠶§¹®ÀÔ´Ï´Ù. ºÒÈ®½Ç¼ºÀÌ ¸¹Àº ¼öÁú¿¡ ´ëÇؼ ¿ª»ïÅõ ¸âºê·¹ÀÎÀº °¡Àå È®½ÇÇÑ ¹æ¹ýÀ» Á¦½ÃÇÕ´Ï´Ù. °¡Á¤¿¡¼ °¡Àå ±ú²ýÇÑ ÀÚ¿¬ »óÅÂÀÇ ¹°À» Áñ±æ ¼ö ÀÖ½À´Ï´Ù. |
|
|
Á¦Ç°¸í |
À¯·®
(GPD,m3/d) |
¿°Á¦°ÅÀ²(%) |
Áö¸§
/±æÀÌ(inch) |
Æò°¡Á¶°Ç |
Á¦Ç°»ç¾ç¼ |
RE3512-900 |
900 (3,407) |
95.0 |
3.5 / 12 |
Household Standard at 80 psi, 40% Recovery |
|
RE3512-TK |
600 (2,271) |
95.0 |
3.5 / 12 |
Dry Integrity Test |
|
RE3012-800 |
800 (3,028) |
96.0 |
3.5 / 12 |
Household Standard at 80 psi, 40% Recovery |
|
RE3012-500 |
500 (1,893) |
97.0 |
3.0 / 12 |
Dry Integrity Test |
|
RE2812-450 |
450 (1,703) |
96.0 |
2.8 / 12 |
Household Standard |
|
RE2812-300* |
350 (1,325) |
97.0 |
2.8 / 12 |
Household Standard |
|
RE2812-HR+* |
300 (1,136) |
99.0 |
2.8 / 12 |
Household Standard |
|
RE2812-CE |
220 (833) |
97.0 |
2.8 / 12 |
Household Standard |
|
RE2012-400* |
400 (1,514) |
96.0 |
2.0 / 12 |
Household Standard at 80 psi |
|
RE2012-150 |
150 (567.8) |
98.0 |
2.0 / 12 |
Household Standard |
|
RE2012-100 |
110 (416) |
98.0 |
2.0 / 12 |
Household Standard |
|
RE2012-LPF |
60 (227) |
93.0 |
2.0 / 12 |
Household LP |
|
RE2012-LP* |
50 (189) |
93.0 |
2.0 / 12 |
Household LP |
|
RE1812-80* |
100 (379) |
98.0 |
1.8 / 12 |
Household Standard |
|
NE1812-70 |
90 (341) |
40-70 (95%) |
1.8 / 12 |
NF Household Standard |
|
RE1812-HR+* |
80 (303) |
99.0 |
1.8 / 12 |
Household Standard |
|
RE1812-50* |
70 (265) |
98.0 |
1.8 / 12 |
Household Standard |
|
RE1812-LP |
30 (114) |
93.0 |
1.8 / 12 |
Household LP |
|
RE1812-60* |
80 (303) |
98.0 |
1.8 / 12 |
Household Standard |
|
RE1810-80* |
80 (303) |
98.0 |
1.8 / 10 |
Household Standard |
|
|
|
|
|
|
Á¦Ç°¸í |
À¯·® (GPD,m3/d) |
¿°Á¦°ÅÀ²(%) |
Áö¸§ /±æÀÌ(inch) |
Æò°¡Á¶°Ç |
Á¦Ç°»ç¾ç¼ |
UE1810* |
200 (757) |
100K |
1.8 / 10 |
20 psi, Pure Water |
|
UE2010* |
450 (1,703) |
100K |
2.0 / 10 |
20 psi, Pure Water |
|
|
|
|
|
Household Standard test conditions: NaCl 200 mg/L, Pressure 60 psig, Temperature 25°C, pH 6.5-7.0 Recovery 15% |
Household LP test conditions: NaCl 100 mg/L, Pressure 20 psig, Temperature 25°C, pH 6.5-7.0 Recovery 15% |
Dry Integrity test conditions: NaCl 200 mg/L, Pressure 60~80 psig, Temperature 25°C, pH 6.5-7.0 Recovery 30~40% |
NF Household Standard test conditions: MgSO4/NaCl 250 mg/L, Pressure 60 psig, Temperature 25°C, pH 6.5-7.0 Recovery 15% |
The stated data were obtained after 30 minutes of operation |
|
|
|
* These models are tested and certified by NSF to NSF/ANSI/CAN 61.
For more certification details,
|
|
|
|
|